Reliant Octel 200 and Octel 300 Message Servers PB6001401 Manuel d'utilisateur Page 226

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 668
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 225
Quick Reference Guide
Octel
Overture 200/300
 
Octel
Overture 200/300 Serenade 3.0
PB60014–01
Section CommandSubject
Integration
Card
TE INT x y Tells
the integration card to run its link selftest.
Used only for systems with integration cards.
x
= slot number
y
= unit number
.
LIC TE L 1 Checks
tone generation and detection circuitry
.
Diagnostics
(continued)
TE L 2 Ring-through
test. Use
only
when
no traf
fic on
system.
TE L 4 x Test
to see whether loop current is present on a
specific port.
x
= port number
.
TE L 5 x Tone
reflection test on one port.
x
= port number
.
Network Routes
TE NET x y Tests
network routes to a network location.
x
= network location code (optional);
y
= non-zero show digits entered.
System Status
TE S Checks
voltages and temperatures.
Fax Application
Processor
TE X x y z Fax
loopback test. V
erifies that the fax modems on
the Fax Application Processor can send and receive
fax data and that the TDM bus connection is
correct.
x
= slot number
y
and
z
= fax channels
Data Fields
BITTST x Converts
hardware error data fields into bit sets.
x
= hexadecimal number
.
Hardware
Errors
List Hardware Error
Table
L H Lists
the Hardware Error T
able.
Clear Hardware
Error Table
C H Clears
the Hardware Error T
able.
Vue de la page 225
1 2 ... 221 222 223 224 225 226 227 228 229 230 231 ... 667 668

Commentaires sur ces manuels