Installing the water heater
DO
DO check inlet gas pressure to ensure that
it is within the range specified on the rating
plate.
DO provide adequate air for combustion
and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas
Code.
DO maintain proper clearances to
combustibles as specified on the rating plate.
DO ensure that the venting system
complies with the guidelines found in the
Use and Care Manual and National Fuel Gas
Code.
DO contact a qualified service technician
if the pilot or main burner will not stay lit.
The burner chamber is designed to be sealed
utilizing a gasket and tamper resistant screws.
DON’T
DON’T block or restrict Combustion
Air Inlet Openings located around the lower
portion of the water heater jacket.
DON’T remove the Burner Access Door
unless absolutely necessary. This should only
be done by a qualified service technician.
A new burner access door gasket must be
installed on any burner access door that has
been removed.
DON’T install this water heater where
standing water may occur. The base of the
water heater is meant to be mounted on a dry
surface.
DON’T operate the water heater if the
sight glass or burner access door grommet is
damaged or broken.
During Installation of this water heater
Burner
Access Door
Grommet
Sight Glass