Reliant FVIR GAS WATER HEATER Guide d'utilisation et d'entretien

Naviguer en ligne ou télécharger Guide d'utilisation et d'entretien pour Chauffe-eau et chaudières Reliant FVIR GAS WATER HEATER. Reliant FVIR GAS WATER HEATER Use & care guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
This water heater complies with ANSI Z21.10.1-current
edition regarding the accidental or unintended ignition of
ammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
• Safety Instructions
• Installation
• Operation
FVIR
GAS WATER HEATER
(FLAMMABLE VAPOR IGNITION RESISTANT)
FOR POTABLE WATER HEATING ONLY.
NOT FOR USE IN MOBILE HOMES.
PRINTED IN THE U.S.A 0910 PART NO. 319554-000
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED.
IF YOU ARE UNSUCCESSFUL, CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1-800-365-4054 OR WWW.RELIANCEWATERHEATERS.COM.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
RESIDENTIAL GAS WATER HEATERS
Installation Instructions and Use & Care Guide
INSTALLER:
AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO THE WATER HEATER.
OWNER:
RETAIN THESE INSTRUCTIONS AND WARRANTY
FOR FUTURE REFERENCE. RETAIN THE
ORIGINAL RECEIPT AS PROOF OF PURCHASE.
WARNING: Gas leaks can not always be detected by
smell.
Gas suppliers recommend that you use a gas detector
approved by UL or CSA.
For more information, contact the your gas supplier.
If a gas leak is detected, follow the “WHAT TO DO IF YOU
SMELL GAS” instructions.
Care and Maintenance
• Troubleshooting
• Parts List
LOW LEAD
COMPLIANT
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - GAS WATER HEATER

1This water heater complies with ANSI Z21.10.1-current edition regarding the accidental or unintended ignition of fl ammable vapors, such as those emit

Page 2 - TABLE OF CONTENTS

10LP Gas Only WARNINGExplosion HazardHave a qualified person make sure L.P. gas pre

Page 3 - SAFETY PRECAUTIONS

11TABLE 3BTUH InputMinimum SquareFeet with8’ CeilingTypical Roomwith 8’ Ceiling30,000 188 9 x 2145,000 281 14 x 2060,000 375 15 x 2575,000 469 15 x 31

Page 4 - Fire or Explosion Harzard

1212” MAXIMUMPERMANENTOPENINGS TOTHE OUTSIDE OR ADDITIONAL ROOMS WITHINTHE BUILDINGCLOSETOR OTHER CONFINED SPACE12” MAXIMUMFIGURE 6.All Air from Insid

Page 5 - A Vent Pipe

13ALTERNATIVEOPENINGLOCATION1 SQ. INCH PER 3000 BTUHCONFINEDSPACEALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENINGFIGURE 11.Vent Pipe System

Page 6

14Align the legs of the draft hood with the slots provided. Insert the draft hood leg tips into slots on the flue damper’s flange as shown in Figure 1

Page 7 - FV Sensor

15Piping Installation Piping, fittings, and valves should be installed according to the installation

Page 8 - FIGURE 4

16SUITABLE DRAINHOT WATEROUTLETCOLD WATERINLETPRESSURE REDUCING VALVE WITH BYPASSCOLD WATER SUPPLY TO FIXTURESCOLD WATER INLET VALVE(SHUT-OFF VALVE)IN

Page 9

17The Discharge Line: • Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line.• M

Page 10 - Explosion Hazard

18□ Fresh air openings sized correctly with consideration given to the blocking effect of louvers and grilles.□ Ductwork is the same cross-sectional

Page 11 - Carbon Monoxide Warning

19WARNINGExplosion HazardReplace view port if glass is missingor damaged.Failure to do so can result in death,explosion or fire.Lighting Instructions

Page 12

2TABLE OF CONTENTSWater Heater Safety ...

Page 13 - FIGURE 10

20Water Temperature Regulation Water temperature over 125°F (52°C) can cause servere burns instantly resulting in se

Page 14 - FIGURE 13

21Gas Control/Temperature KnobStatus LightONOFFSTATUS120°FPositionA B C • •VERYHOTHOTLOWVA CA B C •

Page 15 - WATER SYSTEM PIPING

22ELECTRICAL CONNECTIONS/WIRING DIAGRAMElectrical Connections Before plugging in the water heater, always ma

Page 16 - FIGURE 17

23periods of heat-up and cool-down.2. Condensation causes sizzling and popping within the burner area and should be considered normal.3. Sediment bu

Page 17 - MANUAL RELIEF LEVER

24Anode Rod/Water OdorEach water heater contains at least one anode rod, which will slowly deplete while protecting the glass-lined tank from corrosio

Page 18 - Water Heater Location

25properly. To prevent water damage, the valve must be properly connected to a discharge line which terminates at an adequate drain. Standing clear of

Page 19 - TO TURN OFF GAS TO APPLIANCE

26Removing the Burner from the Manifold/Burner Assembly Natural Gas (Low Nox) & L.P. Gas Burn

Page 20 - Burn Hazard

27Cleaning the Combustion Chamber and Flame-arrestor 1. Follow procedure outlined in “Removing t

Page 21 - Status Light Code

28MANIFOLD TUBEBRACKETTABSLOTBURNERCLOSE-UP INSIDE VIEW OFTHE COMBUSTION CHAMBER.FIGURE 34.Igniter System The

Page 22 - ON/OFF SWITCH

29FVIR System Operational Checklist 1. Manifold gasket properly sealed.2. Viewport not damaged or cracked.3. Fla

Page 23

3SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Page 24 - FIGURE 24

30INSUFFICIENT HOT WATER 1. Thermostat set too low2. Sediment or lime in tank3. Water heater too small4. Wrong piping connections5. Leaking faucet

Page 25 - Explosion Harzard

31STATUS LIGHT TROUBLESHOOTING FLOWCHARTStatus Light CodeLED FLASH SEQUENCECONTROL STATUS CORRECTIVE ACTIONShort flash once every four second IDLE (No

Page 26 - FIGURE 31

32STATUS LIGHT TROUBLESHOOTING FLOWCHARTLED FLASH SEQUENCECONTROL STATUS CORRECTIVE ACTIONSix-Two Flash, three second pause Soft Lockout* - Recycle Li

Page 27

33SEQUENCE OF OPERATION CHARTApply Powerto Appliance.Is Damper Closed?YIs there a Call for Heat.Is Damper Open?Will not attempt to light. 2 flash erro

Page 28 - FIGURE 35

34REPAIR PARTS ILLUSTRATIONLEGENDSpecial anode rod (see Anode Rod/Water Odor section)Temperature and Pressure Relief Valve is required, but may not be

Page 29 - TROUBLESHOOTING CHART

35Listed Parts Kits and IllustrationsItem 12A: Pilot/Igniter-Flame Sensor assembly kit, which contains the pilot, igniter-flame sensor, and retainer

Page 30

36NOTES

Page 31

37NOTES

Page 33 - SEQUENCE OF OPERATION CHART

39THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY in accordance with the warranty terms and conditions specifi ed below.Reliance Water Heater Co

Page 34 - Repair Parts List

4Fire or Explosion HarzardDo not store or use gasoline or other flammable vapors andliquids in the vicinity of this or any other appliance. Avoid all

Page 35 - L.P. BURNER

40Copyright © 2010 Reliance Water Heater Company. All rights reserved. administrative charges, and for any materials and/or permits required for in

Page 36

5TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe B Draft Hood C Anode (Not Shown) D Hot Water Outlet E Insulation F

Page 37

6INSTALLING YOUR GAS WATER HEATERImportant Information About This Water Heater This gas water heater was manufactured to voluntary safety standa

Page 38

7FV SensorFIGURE 1.The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the spec

Page 39 - RESIDENTIAL GAS WARRANTY

8IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to t

Page 40

9CHECK WITHLOCAL UTILITYFOR MINIMUM HEIGHT3” MINIMUMDRIP LEGGROUND JOINTUNIONMANUAL GAS SHUT-OFF VALVESUITABLE DRAIN6” MAXIMUMAIR GAPDISCHARGE PIPE(DO

Commentaires sur ces manuels